Thứ Ba, 9 tháng 8, 2016

Bộ điều khiển lực căng TC680A/D Nireco - Nireco Vietnam

Web Control Systems
Tension Control Systems
Tension Controller TC680A/D
Overview |  Feature |  Specifications | 

 

TC680A-D
Overview
This analog tension controller was designed for easy-to-use, safe control and ease of operation. This intuitive controller, with its simple functionality, is easy for anyone to use.
web_tc680a_d_2nd.jpg
  • Excellent Responsiveness via Constant Loop Gain Circuit
    The control circuit uses Proportional + Integral calculation, providing fast response and high accuracy. Additionally indexed calculation is used to maintain a constant loop gain, regardless of changes in diameter. This maintains high responsiveness without hunting, maintaining appropriate loop gain at all times.
  • Easy to Use and Operate
    The unit can be controlled automatically as long as you have an automatic machine contact. Consequently, the controller is easy for anyone to use, as long as a tension value is set. When stopped, a sequence allows the stopped output value corresponding to the diameter to be obtained.
  • Tension Display
    It is possible to find the total tension, as well as the tension on just one side. Select an analog or digital display to suit your preferences.
  • Wide Range of Applications
    Fits the final control elements of a large number of applications, including air brakes/clutches, air motors, electro-magnetic brakes/clutches, torque motors, and magnetic coupling motors. Select the installation method to suit the location, from panel-mounted, stand-alone, or mounted.
  • Connection with a wide range of tension sensors
    Can be connected to the following wide range of Nireco sensors: MB, MG, MC, CD, MJ, CJ, TSA, and intrinsically safe TSA sensors
  • CE Compliant
    CE marking compliant product
Power voltageAC100 to 240V 50/60Hz
Power consumption320VA (Rush current 60A (200V))
Over voltage category
Current capacity1.6A(200V)
Mass5kg
EnvironmentAmbient temp.0 to +50℃
Ambient hum.35 to 85% RH or less (no condensation)
Vibration3.5 mm, 1G, 3 to 150 Hz, 3 directions (1 hour)
Power noise2,000 Vp-p, normal mode, common mode 50 nS, 1 uS
AtmosphereNo liquid water or flammable or corrosive gas, with low dust levels
Air pollution degree2
Rated tension50, 100, 200, 500, 1000, 2000, 3000, 5000, 10000 N (The scale of the rated tension display is changed to show the various tensions.)
Connectable Tension SensorsMB/MG tension sensor or
MC/CD/MJ/CJ/TSA/Intrinsically safe TSA tension sensor
OutputControl Output0 to 10V (max.5mA), 4 to 20mA
0 to 24V (max.4A)
Display Output0 to 10V (max.1mA), 0 to 1mA
Recorder Output0 to 10V (max.1mA)
External Tension Setting Power10V (max.5mA)
Contact OutputNo. outputs: 1 (30 V DC; 0.2A)
Zero tension
InputSensor InputShared pins
MB/MG/Intrinsically safe TSA tension sensor(connect to pins 1 to 4 & 17 to 20)
MC/CD/MJ/CJ/TSA tension sensor(connect to pins 3 to 6 & 19 to 22)
External Tension Setting Input0 to 10V, input resistance 20 kΩ
Contact InputAuto contact (12 V DC; 10 mA)

Không có nhận xét nào: